Sub-pixel resolution
Script error: No such module "Distinguish". Script error: No such module "Unsubst". In digital image processing, sub-pixel resolution can be obtained in images constructed from sources with information exceeding the nominal pixel resolution of said images.Template:Need sources
Example
Script error: No such module "Unsubst". For example, if the image of a ship of length Script error: No such module "convert"., viewed side-on, is 500 pixels long, the nominal resolution (pixel size) on the side of the ship facing the camera is Script error: No such module "convert".. Now sub-pixel resolution of well resolved features can measure ship movements which are an order of magnitude (10×) smaller. Movement is specifically mentioned here because measuring absolute positions requires an accurate lens model and known reference points within the image to achieve sub-pixel position accuracy. Small movements can however be measured (down to 1 cm) with simple calibration procedures.Script error: No such module "Unsubst". Specific fit functions often suffer specific bias with respect to image pixel boundaries. Users should therefore take care to avoid these "pixel locking" (or "peak locking") effects.[1]
Determining feasibility
Script error: No such module "Unsubst". Whether features in a digital image are sharp enough to achieve sub-pixel resolution can be quantified by measuring the point spread function (PSF) of an isolated point in the image. If the image does not contain isolated points, similar methods can be applied to edges in the image. It is also important when attempting sub-pixel resolution to keep image noise to a minimum. This, in the case of a stationary scene, can be measured from a time series of images. Appropriate pixel averaging, through both time (for stationary images) and space (for uniform regions of the image) is often used to prepare the image for sub-pixel resolution measurements.Template:Need sources
See also
References
<templatestyles src="Reflist/styles.css" />
- ↑ "Accurate particle position measurement from images". Y. Feng, J. Goree, and Bin Liu, Review of Scientific Instruments, Vol. 78, 053704 (2007); also selected for Virtual Journal of Biological Physics Research, Vol. 13, (2007).
Script error: No such module "Check for unknown parameters".
Sources
<templatestyles src="Refbegin/styles.css" />
- Script error: No such module "Citation/CS1".
- Script error: No such module "citation/CS1".
- Script error: No such module "citation/CS1".