Rating plate

From Wikipedia, the free encyclopedia
Jump to navigation Jump to search
File:Rating plate on the Dalchonzie power station generator - geograph.org.uk - 735379.jpg
The rating plate of a generator at the Dalchonzie power station with continuous maximum rating (CMR) of 4 megawatts

A rating plate on a machine carries information about its operational limits. The plate frequently contains the names of the machine and its manufacturer, so the rating plate is often called a name plate (hence the term "nameplate capacity" for a generator), although many devices carry separate nameplates and rating plates.[1]

For an electric machine, the power rating is the number on its rating plate and corresponds to a maximum electric load it can carry. There is a distinction between the continuous rating (for generators, continuous maximum rating or CMR[2]), at which the machine can be operational without a time limit and short-term rating that can only be used for a specified amount of time.[3]

Generators

A typical electrical generator rating plate contains the following parameters:Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters".

  • power rating is specified in terms of apparent power (KVA or MVA), since the exact power factor will be determined by the external factors;Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters".
  • power factor (PF) is the nominal power factor for other ratings; usually PF = 0.8;Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters".
  • insulation class (B, F, H) for the primary coil. Typical value is F, although older generators might use class B;Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters".
  • type of enclosure (IP code);Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters".
  • rated voltage can be either line to line ("line voltage") or phase to neutral ("phase voltage");Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters".
  • rated current is derived from the rated power and voltage: ratedCurrent=apparentPowerlineVoltage;Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters".
  • line frequency (50 Hz or 60 Hz) and rotational speed of the prime mover in RPM;Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters".
  • connection (star or delta).

See also

References

<templatestyles src="Reflist/styles.css" />

  1. Script error: No such module "citation/CS1".
  2. Script error: No such module "citation/CS1".
  3. Script error: No such module "citation/CS1".

Script error: No such module "Check for unknown parameters".

Sources

  • Script error: No such module "citation/CS1".

Template:Asbox