Electrical reactance: Difference between revisions
imported>Fgnievinski Moving from Category:Physical quantities to Category:electrical quantities using Cat-a-lot |
imported>Davemck m Clean up duplicate template arguments using findargdups |
||
| Line 2: | Line 2: | ||
{{use dmy dates|date=May 2021}}{{Redirect|Reactance (physics)||Reactance (disambiguation){{!}}Reactance}} | {{use dmy dates|date=May 2021}}{{Redirect|Reactance (physics)||Reactance (disambiguation){{!}}Reactance}} | ||
In electrical circuits, '''reactance''' is the opposition presented to [[alternating current]] by [[inductance]] and [[capacitance]].<ref name="veley01">{{cite book | | In electrical circuits, '''reactance''' is the opposition presented to [[alternating current]] by [[inductance]] and [[capacitance]].<ref name="veley01">{{cite book |last= Veley |first= Victor F. C. |date= 1987 |title= The Benchtop Electronics Reference Manual |edition= 1st |location= New York |publisher= Tab Books |pages= 229, 232 |url= https://archive.org/details/benchtopelectron00vele }}</ref> It is measured in [[Ohm|ohms]].<ref name="veley01" /> Along with resistance, it is one of two elements of [[Electrical impedance|impedance]]; however, while both elements involve transfer of electrical energy, no [[Joule heating|dissipation of electrical energy as heat]] occurs in reactance; instead, the reactance stores energy until a quarter-cycle later when the energy is returned to the circuit. Greater reactance gives smaller current for the same applied [[voltage]]. | ||
Reactance is used to compute [[amplitude]] and [[Phase (waves)|phase]] changes of [[Sine wave|sinusoidal]] alternating current going through a circuit element. Like resistance, reactance is measured in [[ohm]]s, with positive values indicating ''inductive'' reactance and negative indicating ''capacitive'' reactance. It is denoted by the symbol | Reactance is used to compute [[amplitude]] and [[Phase (waves)|phase]] changes of [[Sine wave|sinusoidal]] alternating current going through a circuit element. Like resistance, reactance is measured in [[ohm]]s, with positive values indicating ''{{dfn|inductive}}'' reactance and negative indicating ''{{dfn|capacitive}}'' reactance. It is denoted by the symbol {{tmath|X}}. An ideal [[resistor]] has zero reactance, whereas ideal reactors have no shunt conductance and no series resistance. As [[frequency]] increases, inductive reactance increases and capacitive reactance decreases. | ||
== Comparison to resistance == | == Comparison to resistance == | ||
| Line 11: | Line 11: | ||
There are several important differences between reactance and resistance, though. First, reactance changes the phase so that the current through the element is shifted by a quarter of a cycle relative to the phase of the voltage applied across the element. Second, power is not dissipated in a purely reactive element but is stored instead. Third, reactances can be negative so that they can 'cancel' each other out. Finally, the main circuit elements that have reactance (capacitors and inductors) have a frequency dependent reactance, unlike resistors which have the same resistance for all frequencies, at least in the ideal case. | There are several important differences between reactance and resistance, though. First, reactance changes the phase so that the current through the element is shifted by a quarter of a cycle relative to the phase of the voltage applied across the element. Second, power is not dissipated in a purely reactive element but is stored instead. Third, reactances can be negative so that they can 'cancel' each other out. Finally, the main circuit elements that have reactance (capacitors and inductors) have a frequency dependent reactance, unlike resistors which have the same resistance for all frequencies, at least in the ideal case. | ||
The term ''reactance'' was first suggested by French engineer Édouard Hospitalier in | The term ''reactance'' was first suggested by French engineer Édouard Hospitalier in {{lang|fr|L'Industrie Electrique}} on 10 May 1893. It was officially adopted by the [[American Institute of Electrical Engineers]] in May 1894.<ref>{{cite journal |last1= Steinmetz |first1= Charles P. |last2= Bedell |first2= Frederick |date= January–December 1894 |title= Reactance |journal= Transactions of the American Institute of Electrical Engineers |volume= 11 |pages= 640–648 |author1-link= Charles Proteus Steinmetz |url= https://ieeexplore.ieee.org/document/4763812 }}</ref> | ||
== Capacitive reactance == | == Capacitive reactance == | ||
| Line 18: | Line 18: | ||
A capacitor consists of two [[Electric conduction|conductor]]s separated by an [[Electrical insulation|insulator]], also known as a [[dielectric]]. | A capacitor consists of two [[Electric conduction|conductor]]s separated by an [[Electrical insulation|insulator]], also known as a [[dielectric]]. | ||
''Capacitive reactance'' is an opposition to the change of voltage across an element. Capacitive reactance <math>X_C</math> is [[inversely proportional]] to the signal [[frequency]] <math>f</math> (or [[angular frequency]] <math>\omega</math>) and the [[capacitance]] | '''Capacitive reactance''' is an opposition to the change of voltage across an element. Capacitive reactance <math>X_C</math> is [[inversely proportional]] to the signal [[frequency]] <math>f</math> (or [[angular frequency]] <math>\omega</math>) and the [[capacitance]] {{tmath|C}}.<ref name="Irwin">{{cite book |last= Irwin |first= D |date= 2002 |title= Basic Engineering Circuit Analysis |page= 274 |location= New York |publisher= John Wiley & Sons }}</ref> | ||
There are two choices in the literature for defining reactance for a capacitor. One is to use a uniform notion of reactance as the imaginary part of impedance, in which case the reactance of a capacitor is the negative number,<ref name="Irwin"/><ref>Hayt | There are two choices in the literature for defining reactance for a capacitor. One is to use a uniform notion of reactance as the imaginary part of impedance, in which case the reactance of a capacitor is the negative number,<ref name="Irwin"/><ref>{{cite book |last1= Hayt |first1= W. H. |last2= Kimmerly |first2= J. E. |date= 2007 |title= Engineering Circuit Analysis |edition= 7th |publisher= McGraw-Hill |page= 388 }}</ref><ref name="Glisson">{{cite book |last= Glisson |first= T. H. |date= 2011 |title= Introduction to Circuit Analysis and Design |publisher= Springer |page= 408 }}</ref> | ||
<math display="block">X_C = -\frac {1} {\omega C} = -\frac {1} {2\pi f C}.</math> | |||
:<math>X_C = | Another choice is to define capacitive reactance as a positive number,<ref>{{cite book |last1= Horowitz |first1= P. |last2= Hill |first2= W. |date= 2015 |title= [[The Art of Electronics]] |edition= 3rd |page= 42}}</ref><ref name="Hughes">{{cite book |last1= Hughes |first1= E. |last2= Hiley |first2= J. |last3= Brown |first3= K. |last4= Smith |first4= I. McK. |date= 2012 |title= Hughes Electrical and Electronic Technology |edition= 11th |publisher= Pearson |pages= 237–241 }}</ref><ref>{{cite book |last1= Robbins |first1= A. H. |last2= Miller |first2= W. |date= 2012 |title= Circuit Analysis: Theory and Practice |edition= 5th |publisher= Cengage Learning |pages= 554–558 }}</ref> | ||
<math display="block">X_C = \frac {1} {\omega C} = \frac {1} {2\pi f C}.</math> | |||
In this case however one needs to remember to add a negative sign for the impedance of a capacitor, i.e. {{tmath|1= Z_c=-jX_c }}. | |||
At {{tmath|1= f=0 }}, the magnitude of the capacitor's reactance is infinite, behaving like an [[wikt:open circuit|open circuit]] (preventing any [[Electric current|current]] from flowing through the dielectric). As frequency increases, the magnitude of reactance decreases, allowing more current to flow. As <math>f</math> approaches {{tmath|\infty}}, the capacitor's reactance approaches {{tmath|0}}, behaving like a [[short circuit]]. | |||
The application of a [[Direct current|DC]] voltage across a capacitor causes positive [[Electrical charge|charge]] to accumulate on one side and negative [[Electrical charge|charge]] to accumulate on the other side; the [[electric field]] due to the accumulated charge is the source of the opposition to the current. When the [[potential]] associated with the charge exactly balances the applied voltage, the current goes to zero. | The application of a [[Direct current|DC]] voltage across a capacitor causes positive [[Electrical charge|charge]] to accumulate on one side and negative [[Electrical charge|charge]] to accumulate on the other side; the [[electric field]] due to the accumulated charge is the source of the opposition to the current. When the [[potential]] associated with the charge exactly balances the applied voltage, the current goes to zero. | ||
| Line 39: | Line 37: | ||
{{main|Inductance}} | {{main|Inductance}} | ||
Inductive reactance is a property exhibited by an inductor, and inductive reactance exists based on the fact that an electric current produces a magnetic field around it. In the context of an AC circuit (although this concept applies any time current is changing), this magnetic field is constantly changing as a result of current that oscillates back and forth. It is this change in magnetic field that induces another electric current to flow in the same wire (counter-EMF) | Inductive reactance is a property exhibited by an inductor, and inductive reactance exists based on the fact that an electric current produces a magnetic field around it. In the context of an AC circuit (although this concept applies any time current is changing), this magnetic field is constantly changing as a result of current that oscillates back and forth. It is this change in magnetic field that induces another electric current to flow in the same wire{{snd}} called [[counter-electromotive force]] (counter-EMF){{snd}} in a direction such as to oppose the flow of the current originally responsible for producing the magnetic field (known as [[Lenz's law]]). Hence, '''inductive reactance''' is an opposition to the change of current through an element. | ||
For an ideal inductor in an AC circuit, the inhibitive effect on change in current flow results in a delay, or a phase shift, of the alternating current with respect to alternating voltage. Specifically, an ideal inductor (with no resistance) will cause the current to lag the voltage by a quarter cycle, or 90°. | For an ideal inductor in an AC circuit, the inhibitive effect on change in current flow results in a delay, or a phase shift, of the alternating current with respect to alternating voltage. Specifically, an ideal inductor (with no resistance) will cause the current to lag the voltage by a quarter cycle, or 90°. | ||
| Line 45: | Line 43: | ||
In electric power systems, inductive reactance (and capacitive reactance, however inductive reactance is more common) can limit the power capacity of an AC transmission line, because power is not completely transferred when voltage and current are out-of-phase (detailed above). That is, current will flow for an out-of-phase system, however real power at certain times will not be transferred, because there will be points during which instantaneous current is positive while instantaneous voltage is negative, or vice versa, implying negative power transfer. Hence, real work is not performed when power transfer is "negative". However, current still flows even when a system is out-of-phase, which causes transmission lines to heat up due to current flow. Consequently, transmission lines can only heat up so much (or else they would physically sag too much, due to the heat expanding the metal transmission lines), so transmission line operators have a "ceiling" on the amount of current that can flow through a given line, and excessive inductive reactance can limit the power capacity of a line. Power providers utilize capacitors to shift the phase and minimize the losses, based on usage patterns. | In electric power systems, inductive reactance (and capacitive reactance, however inductive reactance is more common) can limit the power capacity of an AC transmission line, because power is not completely transferred when voltage and current are out-of-phase (detailed above). That is, current will flow for an out-of-phase system, however real power at certain times will not be transferred, because there will be points during which instantaneous current is positive while instantaneous voltage is negative, or vice versa, implying negative power transfer. Hence, real work is not performed when power transfer is "negative". However, current still flows even when a system is out-of-phase, which causes transmission lines to heat up due to current flow. Consequently, transmission lines can only heat up so much (or else they would physically sag too much, due to the heat expanding the metal transmission lines), so transmission line operators have a "ceiling" on the amount of current that can flow through a given line, and excessive inductive reactance can limit the power capacity of a line. Power providers utilize capacitors to shift the phase and minimize the losses, based on usage patterns. | ||
Inductive reactance <math>X_L</math> is [[Proportionality (mathematics)|proportional]] to the sinusoidal signal [[frequency]] <math>f</math> and the [[inductance]] | Inductive reactance <math>X_L</math> is [[Proportionality (mathematics)|proportional]] to the sinusoidal signal [[frequency]] <math>f</math> and the [[inductance]] {{tmath|L}}, which depends on the physical shape of the inductor: | ||
<math display="block">X_L = \omega L = 2\pi f L.</math> | |||
<math>X_L = \omega L = 2\pi f L</math> | |||
The average current flowing through an [[inductance]] <math>L</math> in series with a [[sinusoidal]] AC voltage source of RMS [[amplitude]] <math>A</math> and frequency <math>f</math> is equal to: | The average current flowing through an [[inductance]] <math>L</math> in series with a [[sinusoidal]] AC voltage source of RMS [[amplitude]] <math>A</math> and frequency <math>f</math> is equal to: | ||
<math display="block">I_L = {A \over \omega L} = {A \over 2\pi f L}.</math> | |||
Because a [[Square wave (waveform)|square wave]] has multiple amplitudes at sinusoidal [[harmonic]]s, the average current flowing through an [[inductance]] <math>L</math> in series with a square wave AC voltage source of RMS [[amplitude]] <math>A</math> and frequency <math>f</math> is equal to: | Because a [[Square wave (waveform)|square wave]] has multiple amplitudes at sinusoidal [[harmonic]]s, the average current flowing through an [[inductance]] <math>L</math> in series with a square wave AC voltage source of RMS [[amplitude]] <math>A</math> and frequency <math>f</math> is equal to: | ||
<math display="block">I_L = {A \pi^2 \over 8 \omega L} = {A\pi \over 16 f L},</math> | |||
making it appear as if the inductive reactance to a square wave was about 19% smaller <math>X_L = {16 \over \pi} f L</math> than the reactance to the AC sine wave. | making it appear as if the inductive reactance to a square wave was about 19% smaller <math>X_L = {16 \over \pi} f L</math> than the reactance to the AC sine wave. | ||
Any conductor of finite dimensions has inductance; the inductance is made larger by the multiple turns in an [[electromagnetic coil]]. [[Faraday's law of induction|Faraday's law]] of electromagnetic induction gives the counter-[[Electromotive force|emf]] <math>\mathcal{E}</math> (voltage opposing current) due to a rate-of-change of [[magnetic flux density]] <math>\scriptstyle{B}</math> through a current loop | Any conductor of finite dimensions has inductance; the inductance is made larger by the multiple turns in an [[electromagnetic coil]]. [[Faraday's law of induction|Faraday's law]] of electromagnetic induction gives the counter-[[Electromotive force|emf]] <math>\mathcal{E}</math> (voltage opposing current) due to a rate-of-change of [[magnetic flux density]] <math>\scriptstyle{B}</math> through a current loop: | ||
<math display="block">\mathcal{E} = -{{d\Phi_B} \over dt}.</math> | |||
For an inductor consisting of a coil with <math>N</math> loops this gives: | For an inductor consisting of a coil with <math>N</math> loops this gives: | ||
<math display="block">\mathcal{E} = -N{d\Phi_B \over dt}.</math> | |||
The counter-emf is the source of the opposition to current flow. A constant [[direct current]] has a zero rate-of-change, and sees an inductor as a [[short-circuit]] (it is typically made from a material with a low [[resistivity]]). An [[alternating current]] has a time-averaged rate-of-change that is proportional to frequency, this causes the increase in inductive reactance with frequency. | The counter-emf is the source of the opposition to current flow. A constant [[direct current]] has a zero rate-of-change, and sees an inductor as a [[short-circuit]] (it is typically made from a material with a low [[resistivity]]). An [[alternating current]] has a time-averaged rate-of-change that is proportional to frequency, this causes the increase in inductive reactance with frequency. | ||
| Line 68: | Line 63: | ||
== Impedance == | == Impedance == | ||
{{main|Electrical impedance}} | {{main|Electrical impedance}} | ||
Both reactance <math> | Both reactance <math>X</math> and [[Electrical resistance|resistance]] <math>R</math> are components of [[Electrical impedance|impedance]] {{tmath|\mathbf{Z} }}: | ||
<math display="block">\mathbf{Z} = R + \mathbf{j}X,</math> | |||
where: | where: | ||
*<math>\mathbf{Z}</math> is the complex [[Electrical impedance|impedance]], measured in [[ohm]]s; | *<math>\mathbf{Z}</math> is the complex [[Electrical impedance|impedance]], measured in [[ohm]]s; | ||
*<math>R</math> is the [[Electrical resistance|resistance]], measured in ohms | *<math>R</math> is the [[Electrical resistance|resistance]], measured in ohms – it is the real part of the impedance <math>{R=\text{Re}{(\mathbf{Z})}}</math>; | ||
*<math>X</math> is the reactance, measured in ohms | *<math>X</math> is the reactance, measured in ohms – it is the imaginary part of the impedance <math>{X=\text{Im}{(\mathbf{Z})}}</math>; and | ||
*<math>\mathbf{j}</math> is the [[Imaginary unit|square root of negative one]], usually represented by <math>\mathbf{i}</math> in non-electrical formulas. <math>\mathbf{j}</math> is used so as not to confuse the imaginary unit with current, commonly represented by | *<math>\mathbf{j}</math> is the [[Imaginary unit|square root of negative one]], usually represented by <math>\mathbf{i}</math> in non-electrical formulas. <math>\mathbf{j}</math> is used so as not to confuse the imaginary unit with current, commonly represented by {{tmath|\mathbf{i} }}. | ||
When both a capacitor and an inductor are placed in series in a circuit, their contributions to the total circuit impedance are opposite. Capacitive reactance <math>X_C</math> and inductive reactance <math>X_L</math> contribute to the total reactance <math>X</math> as follows: | When both a capacitor and an inductor are placed in series in a circuit, their contributions to the total circuit impedance are opposite. Capacitive reactance <math>X_C</math> and inductive reactance <math>X_L</math> contribute to the total reactance <math>X</math> as follows: | ||
<math display="block">{X = X_L + X_C = \omega L -\frac {1} {\omega C}},</math> | |||
where: | where: | ||
*<math>X_L</math> is the [[Inductance|inductive]] reactance, measured in ohms; | *<math>X_L</math> is the [[Inductance|inductive]] reactance, measured in ohms; | ||
*<math>X_C</math> is the [[Capacitance|capacitive]] reactance, measured in ohms; | *<math>X_C</math> is the [[Capacitance|capacitive]] reactance, measured in ohms; and | ||
*<math>\omega</math> is the angular frequency, <math>2\pi</math> times the frequency in [[Hertz|Hz]]. | *<math>\omega</math> is the angular frequency, <math>2\pi</math> times the frequency in [[Hertz|Hz]]. | ||
Hence:<ref name="Glisson"/> | Hence:<ref name="Glisson"/> | ||
*if | *if {{tmath|1= \scriptstyle X > 0 }}, the total reactance is said to be inductive; | ||
*if | *if {{tmath|1= \scriptstyle X = 0 }}, then the impedance is purely resistive; | ||
*if | *if {{tmath|1= \scriptstyle X < 0 }}, the total reactance is said to be capacitive. | ||
Note however that if <math>X_L</math> and <math>X_C</math> are assumed both positive by definition, then the intermediary formula changes to a difference:<ref name="Hughes"/> | Note however that if <math>X_L</math> and <math>X_C</math> are assumed both positive by definition, then the intermediary formula changes to a difference:<ref name="Hughes"/> | ||
<math display="block">{X = X_L - X_C = \omega L -\frac {1} {\omega C}},</math> | |||
but the ultimate value is the same. | but the ultimate value is the same. | ||
=== Phase relationship === | === Phase relationship === | ||
The phase of the voltage across a purely reactive device (i.e. with zero [[Parasitic element (electrical networks)|parasitic resistance]]) | The phase of the voltage across a purely reactive device (i.e. with zero [[Parasitic element (electrical networks)|parasitic resistance]]) {{em|lags}} the current by <math>\tfrac{\pi}{2}</math> radians for a capacitive reactance and {{em|leads}} the current by <math>\tfrac{\pi}{2}</math> radians for an inductive reactance. Without knowledge of both the resistance and reactance the relationship between voltage and current cannot be determined. | ||
:<math>\begin{align} | The origin of the different signs for capacitive and inductive reactance is the phase factor <math>e^{\pm \mathbf{j}{\frac{\pi}{2}}}</math> in the impedance: | ||
\mathbf{Z}_C &= {1 \over \omega C}e^{-\mathbf{j}{\pi \over 2}} = \mathbf{j}\left({ -\frac{1}{\omega C}}\right) = \mathbf{j}X_C \\ | <math display="block">\begin{align} | ||
\mathbf{Z}_L &= \omega Le^{\mathbf{j}{\pi \over 2}} = \mathbf{j}\omega L = \mathbf{j}X_L\quad | \mathbf{Z}_C &= {1 \over \omega C}e^{-\mathbf{j}{\pi \over 2}} = \mathbf{j}\left({ -\frac{1}{\omega C}}\right) = \mathbf{j}X_C, \\ | ||
\mathbf{Z}_L &= \omega Le^{\mathbf{j}{\pi \over 2}} = \mathbf{j}\omega L = \mathbf{j}X_L\quad. | |||
\end{align}</math> | \end{align}</math> | ||
| Line 112: | Line 104: | ||
== References == | == References == | ||
{{Reflist}} | {{Reflist}} | ||
== General references == | |||
* {{cite book |last= Meade |first= R. |date= 2002 |title= Foundations of Electronics |publisher= Cengage Learning }} | |||
* {{cite book |last1= Shamieh |first1= C. |last2= McComb |first2= G. |date= 2011 |title= Electronics for Dummies |publisher= John Wiley & Sons }} | |||
* {{cite book |last1= Young |first1= Hugh D. |last2= Freedman |first2= Roger A. |last3= Ford |first3= A. Lewis |date= 2004 |title= Sears and Zemansky's University Physics |url= https://archive.org/details/relativity00unse |url-access= registration |orig-year= 1949 |edition= 11 |publisher= [[Addison Wesley]] |location= San Francisco |isbn= 0-8053-9179-7}} | |||
== External links == | == External links == | ||
Latest revision as of 19:29, 30 November 2025
Template:Short description Template:Use dmy datesScript error: No such module "redirect hatnote".
In electrical circuits, reactance is the opposition presented to alternating current by inductance and capacitance.[1] It is measured in ohms.[1] Along with resistance, it is one of two elements of impedance; however, while both elements involve transfer of electrical energy, no dissipation of electrical energy as heat occurs in reactance; instead, the reactance stores energy until a quarter-cycle later when the energy is returned to the circuit. Greater reactance gives smaller current for the same applied voltage.
Reactance is used to compute amplitude and phase changes of sinusoidal alternating current going through a circuit element. Like resistance, reactance is measured in ohms, with positive values indicating Template:Dfn reactance and negative indicating Template:Dfn reactance. It is denoted by the symbol Template:Tmath. An ideal resistor has zero reactance, whereas ideal reactors have no shunt conductance and no series resistance. As frequency increases, inductive reactance increases and capacitive reactance decreases.
Comparison to resistance
Reactance is similar to resistance in that larger reactance leads to smaller currents for the same applied voltage. Further, a circuit made entirely of elements that have only reactance (and no resistance) can be treated the same way as a circuit made entirely of resistances. These same techniques can also be used to combine elements with reactance with elements with resistance, but complex numbers are typically needed. This is treated below in the section on impedance.
There are several important differences between reactance and resistance, though. First, reactance changes the phase so that the current through the element is shifted by a quarter of a cycle relative to the phase of the voltage applied across the element. Second, power is not dissipated in a purely reactive element but is stored instead. Third, reactances can be negative so that they can 'cancel' each other out. Finally, the main circuit elements that have reactance (capacitors and inductors) have a frequency dependent reactance, unlike resistors which have the same resistance for all frequencies, at least in the ideal case.
The term reactance was first suggested by French engineer Édouard Hospitalier in Script error: No such module "Lang". on 10 May 1893. It was officially adopted by the American Institute of Electrical Engineers in May 1894.[2]
Capacitive reactance
Script error: No such module "Labelled list hatnote". A capacitor consists of two conductors separated by an insulator, also known as a dielectric.
Capacitive reactance is an opposition to the change of voltage across an element. Capacitive reactance is inversely proportional to the signal frequency (or angular frequency ) and the capacitance Template:Tmath.[3]
There are two choices in the literature for defining reactance for a capacitor. One is to use a uniform notion of reactance as the imaginary part of impedance, in which case the reactance of a capacitor is the negative number,[3][4][5]
Another choice is to define capacitive reactance as a positive number,[6][7][8]
In this case however one needs to remember to add a negative sign for the impedance of a capacitor, i.e. Template:Tmath.
At Template:Tmath, the magnitude of the capacitor's reactance is infinite, behaving like an open circuit (preventing any current from flowing through the dielectric). As frequency increases, the magnitude of reactance decreases, allowing more current to flow. As approaches Template:Tmath, the capacitor's reactance approaches Template:Tmath, behaving like a short circuit.
The application of a DC voltage across a capacitor causes positive charge to accumulate on one side and negative charge to accumulate on the other side; the electric field due to the accumulated charge is the source of the opposition to the current. When the potential associated with the charge exactly balances the applied voltage, the current goes to zero.
Driven by an AC supply (ideal AC current source), a capacitor will only accumulate a limited amount of charge before the potential difference changes polarity and the charge is returned to the source. The higher the frequency, the less charge will accumulate and the smaller the opposition to the current.
Inductive reactance
Script error: No such module "Labelled list hatnote".
Inductive reactance is a property exhibited by an inductor, and inductive reactance exists based on the fact that an electric current produces a magnetic field around it. In the context of an AC circuit (although this concept applies any time current is changing), this magnetic field is constantly changing as a result of current that oscillates back and forth. It is this change in magnetic field that induces another electric current to flow in the same wireTemplate:Snd called counter-electromotive force (counter-EMF)Template:Snd in a direction such as to oppose the flow of the current originally responsible for producing the magnetic field (known as Lenz's law). Hence, inductive reactance is an opposition to the change of current through an element.
For an ideal inductor in an AC circuit, the inhibitive effect on change in current flow results in a delay, or a phase shift, of the alternating current with respect to alternating voltage. Specifically, an ideal inductor (with no resistance) will cause the current to lag the voltage by a quarter cycle, or 90°.
In electric power systems, inductive reactance (and capacitive reactance, however inductive reactance is more common) can limit the power capacity of an AC transmission line, because power is not completely transferred when voltage and current are out-of-phase (detailed above). That is, current will flow for an out-of-phase system, however real power at certain times will not be transferred, because there will be points during which instantaneous current is positive while instantaneous voltage is negative, or vice versa, implying negative power transfer. Hence, real work is not performed when power transfer is "negative". However, current still flows even when a system is out-of-phase, which causes transmission lines to heat up due to current flow. Consequently, transmission lines can only heat up so much (or else they would physically sag too much, due to the heat expanding the metal transmission lines), so transmission line operators have a "ceiling" on the amount of current that can flow through a given line, and excessive inductive reactance can limit the power capacity of a line. Power providers utilize capacitors to shift the phase and minimize the losses, based on usage patterns.
Inductive reactance is proportional to the sinusoidal signal frequency and the inductance Template:Tmath, which depends on the physical shape of the inductor:
The average current flowing through an inductance in series with a sinusoidal AC voltage source of RMS amplitude and frequency is equal to:
Because a square wave has multiple amplitudes at sinusoidal harmonics, the average current flowing through an inductance in series with a square wave AC voltage source of RMS amplitude and frequency is equal to: making it appear as if the inductive reactance to a square wave was about 19% smaller than the reactance to the AC sine wave.
Any conductor of finite dimensions has inductance; the inductance is made larger by the multiple turns in an electromagnetic coil. Faraday's law of electromagnetic induction gives the counter-emf (voltage opposing current) due to a rate-of-change of magnetic flux density through a current loop:
For an inductor consisting of a coil with loops this gives:
The counter-emf is the source of the opposition to current flow. A constant direct current has a zero rate-of-change, and sees an inductor as a short-circuit (it is typically made from a material with a low resistivity). An alternating current has a time-averaged rate-of-change that is proportional to frequency, this causes the increase in inductive reactance with frequency.
Impedance
Script error: No such module "Labelled list hatnote". Both reactance and resistance are components of impedance Template:Tmath: where:
- is the complex impedance, measured in ohms;
- is the resistance, measured in ohms – it is the real part of the impedance ;
- is the reactance, measured in ohms – it is the imaginary part of the impedance ; and
- is the square root of negative one, usually represented by in non-electrical formulas. is used so as not to confuse the imaginary unit with current, commonly represented by Template:Tmath.
When both a capacitor and an inductor are placed in series in a circuit, their contributions to the total circuit impedance are opposite. Capacitive reactance and inductive reactance contribute to the total reactance as follows: where:
- is the inductive reactance, measured in ohms;
- is the capacitive reactance, measured in ohms; and
- is the angular frequency, times the frequency in Hz.
Hence:[5]
- if Template:Tmath, the total reactance is said to be inductive;
- if Template:Tmath, then the impedance is purely resistive;
- if Template:Tmath, the total reactance is said to be capacitive.
Note however that if and are assumed both positive by definition, then the intermediary formula changes to a difference:[7] but the ultimate value is the same.
Phase relationship
The phase of the voltage across a purely reactive device (i.e. with zero parasitic resistance) Template:Em the current by radians for a capacitive reactance and Template:Em the current by radians for an inductive reactance. Without knowledge of both the resistance and reactance the relationship between voltage and current cannot be determined.
The origin of the different signs for capacitive and inductive reactance is the phase factor in the impedance:
For a reactive component the sinusoidal voltage across the component is in quadrature (a phase difference) with the sinusoidal current through the component. The component alternately absorbs energy from the circuit and then returns energy to the circuit, thus a pure reactance does not dissipate power.
See also
References
<templatestyles src="Reflist/styles.css" />
- ↑ a b Script error: No such module "citation/CS1".
- ↑ Script error: No such module "Citation/CS1".
- ↑ a b Script error: No such module "citation/CS1".
- ↑ Script error: No such module "citation/CS1".
- ↑ a b Script error: No such module "citation/CS1".
- ↑ Script error: No such module "citation/CS1".
- ↑ a b Script error: No such module "citation/CS1".
- ↑ Script error: No such module "citation/CS1".
Script error: No such module "Check for unknown parameters".
General references
- Script error: No such module "citation/CS1".
- Script error: No such module "citation/CS1".
- Script error: No such module "citation/CS1".